Zw32 11kv 33kv Automatic Auto Recloser Vcb Outdoor Vacuum

Zw32 11kv 33kv Automatic Auto Recloser Vcb Outdoor Vacuum

Zw32 11kv 33kv Automatic Auto Recloser Vcb Outdoor Vacuum  is an outdoor distribution equipment with rated voltage of 12kV and three-phase  alternating current of 50Hz.It is mainly used to open and close load current, overload current and short circuit current in power system.It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated. The circuit breaker has the characteristics of small volume, light weight, anti-condensation, free maintenance and so on. It can adapt to the harsh weather conditions and dirty environment.

Product Description

ZW32 series outdoor high voltage vacuum circuit breaker  is an outdoor distribution equipment with rated voltage of 12kV and three-phase  alternating current of 50Hz.It is mainly used to open and close load current, overload current and short circuit current in power system.It is suitable for the protection and control in the power distribution system of substation and industrial and mining enterprises, as well as the places where the rural power grid is frequently operated. The circuit breaker has the characteristics of small volume, light weight, anti-condensation, free maintenance and so on. It can adapt to the harsh weather conditions and dirty environment.

Basic Info.

 

Model NO.ZW32-12Arc-extinguishing MediumVacuum
InstallationFixedStructureRecloser
Poles Number3TypeCircuit Breaker
FunctionVacuum Circuit BreakerCertificationISO9001-2000, CE, CCC
Rated Voltage12kvRated FrequencyISO9001-2000, CE, CCC
Mechanical Life10000 TimesRated Current630A
Transport PackageExport Standard Wooden CaseTrademarkCHNGS
OriginChinaHS Code8537209000
Production Capacity500 Pieces/Week

Product Parameters

LtemDescribitionUnitData
1Rated VoltageKV12
2Rated FrequencyHZ50
3Rated CurrentA630
4Rated Short Circuit Breaking CurrentKA20
5Rated peak withstand current (peak)KA50
6Rated short-time withstand currentKA20
7Rated short-time withstand currentKA50
8Mechanical lifeTimes1000
9Rated short circuit breaks numberTimes30
10Power frequency withstand voltage (1min) (wet)(dry)phase to phase/isolating distanceKV42/48
11Lighting impulse withstand voltage (peak) (wet)(dry)phase to phase/isolating distanceKV75/85
12Power frequency withstand voltage ofsecondary circuit
( min)
KV2